161
Earth cable.
3.8.1.3 HD-SDI 1080P 1U Series
The interface is shown as below. See Figure 3-4.
Figure 3-4
Please refer to the following sheet and Figure 3-5 for detailed information.
1234
ALARM 1 to ALARM 4. The alarm becomes active in low voltage.
NO1 C1
NO2 C2
NO3 C3
There are three groups of normal open activation output (on/off
button)
485 A/B
485 communication port. They are used to control devices such as
PTZ. Please parallel connect 120TΩ between A/B cables if there are
too many PTZ decoders.
Earth cable.
3.8.1.4 2HDD 1U Entry-level Series
The interface is shown as below. See Figure 3-5.
Figure 3-5
Please refer to the following sheet and Figure 3-5 for detailed information.
12345
678910
11121314
1516
ALARM 1 to ALARM 8. The alarm becomes active in low voltage.
NO1 C1
NO2 C2
NO3 C3
There are three groups of normal open activation output (on/off
button)
Earth cable.
3.8.1.5 Full-D1 1.5U and Simple 1.5U Series
The 1.5U series product interface is shown as in Figure 3-6.
alarm shop